Advanced Sentinel charging features included as standard:
- Switch mode charging technology: high power efficiency and low heat dissipation, plus wide supply voltage tolerance, in a compact and lightweight package.
- Multistage charging: float, bulk, absorption and AutoBoost stages ensure no compromise between rapid charge recovery and long term battery capacity and life.
- Low output ripple: <1% ripple, beneficial for vented lead acid & NiCd cells, essential for VRLA, and configurable for use as a stand-alone DC power supply.
Items |
![]() 42703850 SNTL300P Model Sentinel 300P Programmable Switch Mode Battery Charger Price $643.58
|
![]() 42703879 ESNTL300PM Model Sentinel 300P Programmable Switch Mode Battery Charger Price $1,009.76
|
![]() 42703875 ESNTL300PCLM Model Sentinel 300P Programmable Switch Mode Battery Charger Price $1,446.56
|
![]() 42703900 SNTL-RTC Model Remote Temperature Sensor Price $45.00
|
![]() 42703851 SNTL300P-FP Model Sentinel 300P Programmable Switch Mode Battery Charger - Fire Pump Approved Price $805.92
|
|||||
Description |
N/A
Open-frame (protective cover) Sentinel 300P. |
N/A
Enclosed Sentinel 300P. |
N/A
Enclosed Sentinel 300P. |
N/A Remote temperature sensor with 9.8 feet/3.0 meter lead assembly, for automatic charge output temperature compensation. |
N/A
|
|||||
Model Number | N/A SNTL300P | N/A ESNTL300PM | N/A ESNTL300PCLM | N/A SNTL-RTC | N/A SNTL300P-FP | |||||
Alternate Current (AC) Operating Voltage | N/A 95 to 250 V | N/A 95 to 250 V | N/A 95 to 250 V | N/A | N/A 95 to 250 V | |||||
Operating Frequency | N/A 47 to 63 Hz | N/A 47 to 63 Hz | N/A 47 to 63 Hz | N/A | N/A 47 to 63 Hz | |||||
Direct Current (DC) Nominal Voltage1 | N/A 12 V24 V | N/A 12 V24 V | N/A 12 V24 V | N/A | N/A 12 V24 V | |||||
Maximum Current Limit | N/A 10 A | N/A 10 A | N/A 10 A | N/A | N/A 10 A | |||||
Voltage Ripple | N/A <1 % | N/A <1 % | N/A <1 % | N/A | N/A <1 % | |||||
Line Regulation | N/A <2 % | N/A <2 % | N/A <2 % | N/A | N/A <2 % | |||||
Load Regulation | N/A <2 % | N/A <2 % | N/A <2 % | N/A | N/A <2 % | |||||
Outputs x3 (x4 for Non-CAN Configurations) | N/A 1 x SPCO (RL1), 1 x SPNC (RL2), 1 x SPNO (RL3), dry/volt-free contacts (common feed for RL1, RL2 & RL3) | N/A 1 x SPCO (RL1), 1 x SPNC (RL2), 1 x SPNO (RL3), dry/volt-free contacts (common feed for RL1, RL2 & RL3) | N/A 1 x SPCO (RL1), 1 x SPNC (RL2), 1 x SPNO (RL3), dry/volt-free contacts (common feed for RL1, RL2 & RL3) | N/A | N/A 1 x SPCO (RL1), 1 x SPNC (RL2), 1 x SPNO (RL3), dry/volt-free contacts (common feed for RL1, RL2 & RL3) | |||||
Standard Models (Non-CAN Configurations) | N/A 1 x SPNC (RL4), dry/volt-free contacts standard output functions (charge fail, AC fail, low battery volts, high battery volts) are NFPA 110 compliant. | N/A 1 x SPNC (RL4), dry/volt-free contacts standard output functions (charge fail, AC fail, low battery volts, high battery volts) are NFPA 110 compliant. | N/A 1 x SPNC (RL4), dry/volt-free contacts standard output functions (charge fail, AC fail, low battery volts, high battery volts) are NFPA 110 compliant. | N/A | N/A 1 x SPNC (RL4), dry/volt-free contacts standard output functions (charge fail, AC fail, low battery volts, high battery volts) are NFPA 110 compliant. | |||||
Maximum Current Rating at 30 Direct Current (DC) Voltage2 | N/A 1 A | N/A 1 A | N/A 1 A | N/A | N/A 1 A | |||||
Standards for Maximum Current Rating at 30 Direct Current (DC) Voltage | N/A UL Class 2 | N/A UL Class 2 | N/A UL Class 2 | N/A | N/A UL Class 2 | |||||
Inputs x2 | N/A Closed to negative DC to activate, configurable function | N/A Closed to negative DC to activate, configurable function | N/A Closed to negative DC to activate, configurable function | N/A | N/A Closed to negative DC to activate, configurable function | |||||
Operating Temperature | N/A -40 to 60 ºC-40 to 140 ºF | N/A -40 to 60 ºC-40 to 140 ºF | N/A -40 to 60 ºC-40 to 140 ºF | N/A | N/A -40 to 60 ºC-40 to 140 ºF | |||||
Display Viewability (Liquid Crystal Display (LCD) Models) | N/A 0 to 50 ºC32 to 122 ºF | N/A 0 to 50 ºC32 to 122 ºF | N/A 0 to 50 ºC32 to 122 ºF | N/A | N/A 0 to 50 ºC32 to 122 ºF | |||||
Relative Humidity | N/A 20 to 90 % | N/A 20 to 90 % | N/A 20 to 90 % | N/A | N/A 20 to 90 % | |||||
Electrical Safety | N/A 2006/95/EC | N/A 2006/95/EC | N/A 2006/95/EC | N/A | N/A 2006/95/EC | |||||
Electromagnetic Compatibility | N/A 2004/108/EC EN 55022 Class B (EN 61000-6-1, EN 61000-6-3) | N/A 2004/108/EC EN 55022 Class B (EN 61000-6-1, EN 61000-6-3) | N/A 2004/108/EC EN 55022 Class B (EN 61000-6-1, EN 61000-6-3) | N/A | N/A 2004/108/EC EN 55022 Class B (EN 61000-6-1, EN 61000-6-3) | |||||
UL Approvals | N/A BBGQ: UL1236, CSA22.2 no. 107.2 BBHH: UL1236 SE | N/A BBGQ: UL1236, CSA22.2 no. 107.2 BBHH: UL1236 SE | N/A BBGQ: UL1236, CSA22.2 no. 107.2 BBHH: UL1236 SE | N/A | N/A BBGQ: UL1236, CSA22.2 no. 107.2 BBHH: UL1236 SE | |||||
Overall Width (W) | N/A 6.22 in158 mm | N/A 6.50 in165 mm | N/A 6.50 in165 mm | N/A | N/A 6.22 in158 mm | |||||
Overall Height (H) | N/A 8.19 in208 mm | N/A | N/A | N/A | N/A 8.19 in208 mm | |||||
Overall Height (H1) | N/A | N/A 11.81 in300 mm | N/A 11.81 in300 mm | N/A | N/A | |||||
Overall Height (H2) | N/A | N/A 3.15 in80 mm | N/A 3.15 in80 mm | N/A | N/A | |||||
Overall Depth (D) | N/A 3.31 in84 mm | N/A | N/A | N/A | N/A 3.31 in84 mm | |||||
Overall Depth (D1) | N/A | N/A 4.92 in125 mm | N/A 4.92 in125 mm | N/A | N/A | |||||
Overall Depth (D2) | N/A | N/A 5.12 in130 mm | N/A 5.12 in130 mm | N/A | N/A | |||||
Fixing Holes (X) | N/A 5.91 in150 mm | N/A 2.50 in63.5 mm | N/A 2.50 in63.5 mm | N/A | N/A 5.91 in150 mm | |||||
Fixing Holes (Y) | N/A 5.91 in150 mm | N/A 11.25 in285.5 mm | N/A 11.25 in285.5 mm | N/A | N/A 5.91 in150 mm | |||||
Weight | N/A 2.5 lb1.1 kg | N/A 4.4 to 4.6 lb2.0 to 2.1 kg | N/A 4.4 to 4.6 lb2.0 to 2.1 kg | N/A | N/A 2.5 lb1.1 kg | |||||
Industry Standards | N/A CE cRU NFPA 110 | N/A CE cULus NFPA 110 | N/A CE cULus NFPA 110 | N/A | N/A CE cRU NFPA 110 | |||||
Electrical Connections |
N/A
![]() Electrical Connections for Sentinel 300P Programmable Switch Mode Battery Chargers |
N/A
![]() Electrical Connections for Sentinel 300P Programmable Switch Mode Battery Chargers |
N/A
![]() Electrical Connections for Sentinel 300P Programmable Switch Mode Battery Chargers |
N/A
|
N/A
![]() Electrical Connections for Sentinel 300P Programmable Switch Mode Battery Chargers |
|||||
Output Calibration Information |
N/A
Battery type is selected by circuit board DIP switches or SNTL300P-PCSUITE configuration software. |
N/A
Battery type is selected by circuit board DIP switches or SNTL300P-PCSUITE configuration software. |
N/A
Battery type is selected by circuit board DIP switches or SNTL300P-PCSUITE configuration software. |
N/A |
N/A
Battery type is selected by circuit board DIP switches or SNTL300P-PCSUITE configuration software. |
|||||
Output Calibration Specification Table |
N/A
![]() Output Calibration Specification Table for Sentinel 300P Programmable Switch Mode Battery Chargers |
N/A
![]() Output Calibration Specification Table for Sentinel 300P Programmable Switch Mode Battery Chargers |
N/A
![]() Output Calibration Specification Table for Sentinel 300P Programmable Switch Mode Battery Chargers |
N/A
|
N/A
![]() Output Calibration Specification Table for Sentinel 300P Programmable Switch Mode Battery Chargers |
|||||
AutoBoost |
N/A
Triggered automatically on low charge levels, or manually by remote switch, AutoBoost temporarily increases the charge voltage before returning to float mode. Equalizing battery cell charge without overcharge and gassing, AutoBoost maximizes cell capacity and life. |
N/A
Triggered automatically on low charge levels, or manually by remote switch, AutoBoost temporarily increases the charge voltage before returning to float mode. Equalizing battery cell charge without overcharge and gassing, AutoBoost maximizes cell capacity and life. |
N/A
Triggered automatically on low charge levels, or manually by remote switch, AutoBoost temporarily increases the charge voltage before returning to float mode. Equalizing battery cell charge without overcharge and gassing, AutoBoost maximizes cell capacity and life. |
N/A |
N/A
Microprocessor programmability for automatic or manual configuration of charge output voltages (12 or 24 V nominal), cell types/numbers and application - all in one standard model. Programming is by circuit board links or PC - based software configuration and monitoring tool. |
|||||
Temperature Compensation |
N/A
Microprocessor programmability for automatic or manual configuration of charge output voltages (12 or 24 V nominal), cell types/numbers and application - all in one standard model. Programming is by circuit board links or PC - based software configuration and monitoring tool. |
N/A
For remote charger control, and signaling of charge fail, high/low battery volts and mains fail faults. Standard output functions are NFPA 110 compliant. Non-standard input/output functions available to special order. |
N/A
Ensures batteries are charged at the optimal voltage, which varies significantly with ambient temperature. Sentinel can measure temperature with a battery-mounted sensor and adjusts output voltage to prevent under or over charging. |
N/A |
N/A
Microprocessor programmability for automatic or manual configuration of charge output voltages (12 or 24 V nominal), cell types/numbers and application - all in one standard model. Programming is by circuit board links or PC - based software configuration and monitoring tool. |
|||||
Flexible Configuration |
N/A
For remote charger control, and signaling of charge fail, high/low battery volts and mains fail faults. Standard output functions are NFPA 110 compliant. Non-standard input/output functions available to special order. |
N/A
For remote charger control, and signaling of charge fail, high/low battery volts and mains fail faults. Standard output functions are NFPA 110 compliant. Non-standard input/output functions available to special order. |
N/A
Microprocessor programmability for automatic or manual configuration of charge output voltages (12 or 24 V nominal), cell types/numbers and application - all in one standard model. Programming is by circuit board links or PC - based software configuration and monitoring tool. |
N/A |
N/A
Microprocessor programmability for automatic or manual configuration of charge output voltages (12 or 24 V nominal), cell types/numbers and application - all in one standard model. Programming is by circuit board links or PC - based software configuration and monitoring tool. |
|||||
Inputs and Outputs |
N/A
For remote charger control, and signaling of charge fail, high/low battery volts and mains fail faults. Standard output functions are NFPA 110 compliant. Non-standard input/output functions available to special order. |
N/A
Tested and approved by UL to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. |
N/A
For remote charger control, and signaling of charge fail, high/low battery volts and mains fail faults. Standard output functions are NFPA 110 compliant. Non-standard input/output functions available to special order. |
N/A |
N/A
Options for backlit LCD readout, analogue metering and CAN 2.0B/SAE J1939 data communication; all models include RS485 communication for configuration and control. |
|||||
Display, Instrumentation and Communication |
N/A
Options for backlit LCD readout, analogue metering and CAN 2.0B/SAE J1939 data communication; all models include RS485 communication for configuration and control. |
N/A
Tested and approved by UL to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. |
N/A
Options for backlit LCD readout, analogue metering and CAN 2.0B/SAE J1939 data communication; all models include RS485 communication for configuration and control. |
N/A |
N/A
Options for backlit LCD readout, analogue metering and CAN 2.0B/SAE J1939 data communication; all models include RS485 communication for configuration and control. |
|||||
Note |
N/A
Tested and approved by UL to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. |
N/A
Tested and approved by UL to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. |
N/A
Tested and approved by UL to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. |
N/A |
N/A
Tested and approved by UL to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. |
|||||
|