Enclosed Sentinel UL150, 10 A/12 V vented lead acid output, 110/120/220/240 VAC (50 Hz/60 Hz) input.
Power Supply
| Alternate Current (AC) Operating Voltage | N/A 95 to 250 V | 
| Operating Frequency | N/A 47 to 63 Hz | 
Direct Current (DC) Charge Output
| Direct Current (DC) Nominal Voltage | N/A 12 V | 
| Maximum Current Limit | N/A 5 A10 A | 
| Voltage Ripple | N/A <1 % | 
| Line Regulation | N/A <2 % | 
| Load Regulation | N/A <2 % | 
Alarm Outputs
| Charge Fail, Mains Alternate Current (AC) Fail | N/A +DC During Normal Charge 1 x Solid-State Relay Open Circuit During Fault | 
| Maximum Current Rating at 30 Direct Current (DC) Voltage (All Relay Outputs)1 | N/A 250 mA | 
| Standards for Maximum Current Rating at 30 Direct Current (DC) Voltage (All Relay Outputs) | N/A UL Class 2 | 
| Alarm Outputs Information | N/A Sentinel UL150 models include a self-diagnostic circuit for monitoring charge fail fault conditions (AC supply/fuse failure, DC fuse failure or low/no charge current), with a solid-state relay output for driving a remote alarm or fault annunciator. Enclosed NFPA models have NFPA 110 compliant alarms for AC failure, charge fail, high battery volts and low battery volts. | 
Physical
| Operating Temperature | N/A -4 to 140 ºF-20 to 60 ºC | 
| Relative Humidity | N/A 20 to 90 % | 
| Electrical Safety | N/A 2006/95/EC | 
| Electromagnetic Compatibility | N/A 2004/108/EC (EN 61000-6-2, EN 61000-6-4) | 
Dimensions
| Overall Width (W) | N/A 4.72 in120 mm | 
| Overall Height (H1) | N/A 10.51 in267 mm | 
| Overall Height (H2) | N/A 2.76 in70 mm | 
| Overall Depth (D1) | N/A 3.74 in95 mm | 
| Overall Depth (D2) | N/A 5.12 in130 mm | 
| Fixing Holes (X) | N/A 2.50 in63.5 mm | 
| Fixing Holes (Y) | N/A 10.04 in255 mm | 
| Weight | N/A 2.8 lb1.25 kg | 
Standard Output Calibration
Features
| Features | N/A AutoBoost provides a temporary increase in output voltage, equalizing the charge between cells and maximizing battery life and capacity. AutoBoost is triggered automatically when the battery falls below a preset voltage or can be initiated manually through a momentary switch input. At the end of the AutoBoost cycle, Sentinel automatically reverts to normal float charge mode, preventing battery over-charge and gassing. | 
AutoBoost
| AutoBoost | N/A UL-recognized SNTLUL150 model uses an open frame circuit board and base/heatsink with protected cover, for surface or DIN rail mounting in an existing control panel. UL-listed ESNTLUL150 models use a stainless steel, wall-mounted case. | 
Temperature Compensation
| Temperature Compensation | N/A UL-recognized SNTLUL150 model uses an open frame circuit board and base/heatsink with protected cover, for surface or DIN rail mounting in an existing control panel. UL-listed ESNTLUL150 models use a stainless steel, wall-mounted case. | 
Installation and Connection
| Installation and Connection | N/A UL-recognized SNTLUL150 model uses an open frame circuit board and base/heatsink with protected cover, for surface or DIN rail mounting in an existing control panel. UL-listed ESNTLUL150 models use a stainless steel, wall-mounted case. | 
Note
| Note | N/A UL Tested (listed or recognized) to: UL1236 - Battery chargers for charging engine-starting batteries, and CSA22.2 No. 107.2 - Battery chargers. | 
- 1 Resistive load



 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                 
                                